Outputs MenuPage 41Set Fail (38)Active when a set command fails. Remains active until the user acknowledges theset fail.Zone Follow (39)Active when any selected zone is active, irrespective of whether the zone is set orunset. The zones can include Log Only zones. Specify the zones using the Zonesoption (see page 43).Zone Alarm (40)Active when any selected zone is in alarm. Note: The zone must be capable of causing an alarm, such as zones of type Fire Alarm,Normal Alarm, Entry Route, Tamper, 24 Hour and Technical. A Final Exit zone willalso cause an alarm if the Entry Time runs out before the user unsets the system. The zone must be set, unless it is a Fire Alarm zone. The system must be full set,or the zone must belong to the part set that the user has selected.The output deactivates when the alarm is reset. Specify the zones using the Zonesoption (see page 43).User Defined (43)Activated when by any one of the following events: A user operates the output from the User Menu – Outputs On/Off option. A user presses one of the A, B, C or D keys that the installer has configured tooperate a user-defined output.When you select this type, you can choose: Polarity – See page 43. Latched – When set to No, the output changes state when activated, but thenreturns to the normal state again after the period specified by On Time (seebelow). When set to Yes, the output changes state every time a user operates theoutput, or according to a schedule if you specify On Time, Off Time and Days(see below). On Time/Off Time/Days – If Latched is set to No, use On Time to specify thenumber of seconds you want the output to remain active. If you specify zeroseconds, the output will not operate.If Latched is set to Yes: You can use On Time, Off Time and Days to specify a schedule for the outputto activate and deactivate automatically. Use On Time and Off Time to specifythe time you want the output to activate and deactivate. Use Days to specifythe days of the week you want the output to operate.Note: If a user activates the output while it is deactivated, the output staysactivated until the control unit reaches the next off time. If a user de-activatesthe output while it is activated, the output deactivates until the control unitreaches the next on time. Leave On Time, Off Time and Days without values if you want the output toact as a simple on/off switch under the control of the user.Line Fault (44)Active when the control unit detects a communications fault. Deactivates when thecommunications fault clears