Eaton Scantronic i-on10 Configuration Manual
Also see for Scantronic i-on10: Installation instructions
Log MessagesPage 67"Entry Stray Z==" Stray on entry alarm at zone n"Ext WD Fault Z===" A warning device has reported afault through zone n"Ext WD Restr Z===" The fault reported through zone nby a warning device has beenrestored"Fire Reset" User reset system after fire alarm"Fire Z== Alarm" Fire alarm on zone n"Fire Z== Restore" Fire alarm on zone n restored"HU == Alarm" Hold Up alarm at keypad n"HUA Cnf RF HD U---" Hold Up Alarm confirmed by radioHUD belonging to user"HUA Cnf RF MD U---" Hold Up Alarm confirmed by radioMan Down transmitter belonging touser n"HUA Conf Bus# Tamp" Hold Up Alarm by a bus tamper"HUA Conf HD ==" Hold Up Alarm confirmed onkeypad n HUA keys"HUA Conf Panel Lid" Hold Up Alarm confirmed by panellid tamper"HUA Conf. ==ER" Hold Up Alarm has been confirmedby a missing external prox readeron keypad n"HUA Confirm ==" Hold Up Alarm confirmed onkeypad HUA keys"HUA Confirm Bell #" Hold Up Alarm confirmed bycontrol unit Tamper Return (TR)"HUA Confirm WAM==" Hold Up Alarm confirmed bytamper on WAM n"HUA Confirm Z===" Hold Up Alarm confirmed on wiredzone n"HUA Confirm" Hold Up Alarm confirmed on device"HUA Restore P#" Hold Up alarm at keypad restoredfor partition n"HUA Restore" Hold Up Alarm has been restored"HUA Z== Alarm" Hold Up alarm on zone n"HUA Z== Restore" Hold Up alarm restored on zone n"HUD Fault Rst Z===" A hold up device fault reported onzone n was restored"HUD Fault Z===" A hold up device reported a faulton zone n"Inv Login Attpt KP" Invalid access code entered onkeypad"Inv Login Attpt PX" Invalid prox tag presented tokeypad"Inv Login Attpt RM" Invalid remote access attempt"K== Excess Keys" Excess keys tamper at keypad n"Key Sw Ptn # PtSet" Partition part set from keyswitch"Key Sw Ptn # Set" Partition n set from keyswitch"Key Sw Ptn # Unset" Partition n unset from keyswitch"Key Sw System PtSet" System part set from keyswitch"Key Sw System Set" System set from keyswitch"Key Sw System Unset" System unset from keyswitch"Keypad == added" New keypad n added to system"Keypad == found" New keypad n found on bus"Kpd == deleted" Keypad deleted from system"Lid Tamper Restore" Control unit lid closed"Lockset Z=== Set" Zone n with type "lock set" wasclosed (If Inverted attribute is set to"normal")"Lockset Z=== Unset" Zone n with type "lock set" wasopened (If Inverted attribute is setto "normal")"Login Keypad" Valid access code entered onkeypad"Login Prox" Valid prox tag presented to keypad"Low Batt = Restore" Control unit battery no longer low"Low Battery =" Control unit battery low"Missing == Rstr" Missing keypd n restored to bus"Missing ==" Keypad n missing from bus"Missing ==ER Rs" An External prox Readerconnected to keypad n has beenre-connected"Missing ==ER" An External prox Readerconnected to keypad n has gonemissing (possibly disconnectedfrom the keypad)"Occupancy Set P#" Set but with Occupancy zone(s)open"Panel A/C Fail" AC power failure at control unit"Panel A/C Restore" AC power restored at control unit"Panel lid open" Control unit lid open"Remote Reset" User reset system remotely"Set Fail Z==" Setting failed at zone"Soak Fail Z== Alm" Zone n on soak test failed"Soak Fail Z== Tmp" Zone n on soak test tampered"Software Changed" New control unit software has beeninstalled"System Error" Control unit has fault in mainprocessor"System Rearmed" User rearmed the system"System Startup" The system restarted after a powerfail (mains and battery)"Tamper == Rstr" Tamper at keypad n restored"Tamper ==" Tamper at keypad n"Tamper ==ER Rst" Tamper at external reader nrestored"Tamper ==ER" Tamper at external reader n"Tamper Z== Restore" Zone n tamper restored"Tamper Z==" Zone n tamper"Tech Z== Alarm" Technical alarm on zone n"Tech Z== Restore" Technical alarm on zone n restored"U-- Change U==" User n changed their password"U-- Config Change" User n changed programmingconfiguration"U-- Delete U==" User n deleted another User n fromsystem"U--- Duress Restr" User n keyed in a Duress code tounset the system (part settingsystem)"U--- Duress" User n keyed in a Duress code toset the system (part settingsystem)"U--- O/P === Off" User defined output swittched onby user n |
Related manuals for Eaton Scantronic i-on10
Eaton Scantronic i-on30R+ User Manual
Eaton i-on16 Installation Manual
Eaton i-on1000EX Installation Manual
Eaton i-on160EX Installation Manual
Eaton i-on Style Manual
Eaton i-on40 Installation Manual
Eaton i-on30EX Installation Manual
Eaton i-on50EX Installation Manual
Eaton i-on Compact User Manual
Eaton i-on30EXL Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine