Settings Options MenuPage 46Exit TimeThis option is available only if Exit Mode is set to Timed Set or Silent Set. The exit timecan take any value between 10s and 120s.Entry TimeThe entry time can take any value between 10s and 120s. The entry time you select in thisoption applies to full set and all part sets.To comply with EN50131-1 Clause 8.3.8.2, maximum is 45s for Entry Time.Extended Entry TimeThis defines the entry time for Final Exit zone types that have the Extended Entry Timeattribute enabled (see page 31).Alarm ResponseNote: This is available only for a part set. The response for a full set is always Siren +Comms.InternalKeypads and loudspeakers.SirenExternal sirens, keypads and loudspeakers.Siren + CommsCommunication, external sirens, keypads and loudspeakers.Note that any Siren Delay (see page 46) applies to Siren+Comms, but not Internal orSiren alarm responses.Siren DelayYou can use this option to delay the sounding of a confirmed alarm.If System Options – Confirmation – Sounder On is set to Confirm (see page 54), SirenDelay delays the sound at keypads and loudspeakers for the specified period after theconfirmed alarm.If System Options – Confirmation – Siren On is set to Confirm (see page 55), Siren Delaydelays the sound at the external siren for the specified period after the confirmed alarm.The system then operates the siren and sounders for the programmed Siren Time. Seealso "Sounder and siren operation" on page 54.Note: Siren Delay has no effect if Alarm Response (page 46) is not set to Siren + Comms,or if a line fault is detected.Siren TimeThis option changes the length of time that the system operates the siren andloudspeakers during an alarm.Note: To comply with EN50131-1 Clause 8.6, the minimum is 90s, and the maximum is15mins.Pt.set Final ExitNote: This is available only for a part set. This option controls how the system uses FinalExit zones when the system is part set.