ARINC 429/575 Six Channel, Tx/Rx (Module A4)68C3 Operations Manual North Atlantic Industries, Inc. 12/19/2014Rev: 2014-12-19-0947 www.naii.com Page 61 of 330Interrupt EnableType: binary wordRange: not applicableRead/Write: R/WInitialized Value: not applicableThis register provides for Interrupt Enabling. Set bit high True to enable interrupts. Status will still be reported instatus registers. See specific registers for function description and programming.REGISTER D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 FUNCTIONINTERRUPT ENABLE 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 RX DATA AVAILABLE0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 RX FIFO ALMOST FULL0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 RX FIFO FULL0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 RX FIFO OVERFLOW0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 TX FIFO EMPTY0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 TX FIFO ALMOST EMPTY0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 RESERVED0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 PARITY ERROR0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 RECEIVE ERROR0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 BUILT-IN-TEST ERROR0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 SCHEDULE INTERRUPT0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 ASYNC DATA SENT0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 TX COMPLETE0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 RESERVED0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 RESERVED1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 RESERVED