Four Channel, Serial (RS232/422/485) (Module P8) /Isolated RS-422/RS-485 (Module PC)68C3 Operations Manual North Atlantic Industries, Inc. 12/19/2014Rev: 2014-12-19-0947 www.naii.com Page 96 of 330Channel Control ExtendedType: binary wordRange: not applicableRead/Write: R/WInitialized Value: 0This register is used to control real-time Sync operationREGISTER D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 FUNCTIONCONTROL EXT 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Write 1= enter hunt modeRead 0=hunting, 1 = in syncData ConfigurationType: binary wordRange: not applicableRead/Write: R/WInitialized Value: 0This register is used for channel data configuration.REGISTER D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 FUNCTIONDATA CONFIG 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 9 DATA BITS0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 DATA BITS0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 7 DATA BITS0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 6 DATA BITS0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 5 DATA BITS0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 NO PARITY0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 SPACE PARITY0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 ODD PARITY0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 EVEN PARITY0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 MARK PARITY0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 STOP BIT0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 2 STOP BITS0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 NRZ DATA ENCODING0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 NRZI DATA ENCODING0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 FM0 DATA ENCODING0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 FM1 DATA ENCODING0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 MANCHESTER DATA ENCODING