February, 20082-103WorkCentre 5225, 5230 012-161 (A-Finisher), 012-211 (A-Finisher)Status Indicator RapsLaunch VersionCheck the wires and connectors for an intermittent open or short circuit. If the problemcontinues, replace the Finisher PWB (PL 22.7).Enter [012-054] and [012-056] alternately. The Eject Motor rotates.Y NCheck the connections of P/J8706 and P/J8741. P/J8706 and P/J8741 are securelyconnected.Y NConnect P/J8706 and P/J8741 securely.Check for an open or short circuit between J8706 and J8741. The wires betweenJ8706 and J8741 are OK.Y NRepair the open or short circuit.Measure the voltage between Finisher PWB J8706-13 (+) and GND (-), and betweenJ8706-15 (+) and GND (-). The voltage is approx. +24VDC.Y NGo to Wirenet A-Finisher +24VDC and check the +24VDC circuit.Check the Eject Motor drive mechanism for deformed parts, broken parts, and/or beltdamage The drive mechanism free from defects.Y NRepair defects or damage to the drive mechanism.Replace the Eject Motor (PL 22.9). If the problem continues, replace the Finisher PWB(PL 22.7).Check the wires and connectors for an intermittent open or short circuit. If the problem contin-ues, replace the Finisher PWB (PL 22.7).012-211 (A-Finisher) Stacker Tray FailBSD-ON:12.8• Within a specified time after the Stacker Tray started lifting up, the Stack Height Sensordid not detect the lifting up of the Stacker Tray.• Within a specified time after the Stacker Tray started going down at initialization and dur-ing a job, the lower position of the tray (Full) could not be detected based on the changesin the Stacker Stack Sensor 1 and the Stacker Stack Sensor 2.Initial Actions• Check the Stack Height Sensor is properly installed, not broken, and has no foreignobject.• Check the Stacker Stack Sensors 1 and 2 are properly installed and have no foreignobjects and that their actuators are not broken.• Power Off/On.ProcedureCheck the drive mechanism to the Stacker Tray for a deformed or broken part and not-seatedgears. The mechanism is free from defects and the gears seat properly.Y NRepair the mechanism.Run DC330[012-267].Enter Component Control [012-267]. Block and unblock the Stack Height Sensor with a pieceof paper. The display changes.Y NCheck the connections of P/J8708 and P/J8727. P/J8708 and P/J8727 are securelyconnected.Y NConnect P/J8708 and P/J8727 securely.Check for an open or short circuit between J8708 and J8727. The wire between J8708and J8727 are OK.Y NRepair the open or short circuit.Measure the voltage between Finisher PWB J8708-3 (+) and GND (-). The voltage isapprox. +5VDC.Y NGo to Wirenet 7.2.36 A-Finisher +5VDC and check the +5VDC circuit.Measure the voltage between Finisher PWB J8708-2 (+) and GND (-). Block and unblockthe Stack Height Sensor with a piece of paper. The voltage changes.Y NReplace the Stack Height Sensor (PL 22.10).Check the wires and connectors for an intermittent open or short circuit. If the problemcontinues, replace the Finisher PWB (PL 22.7).A BA