February, 20082-57WorkCentre 5225, 5230 005-123Status Indicator RapsLaunch Version005-123 CVT Simplex/Side1 Registration JAM RAPAfter pre-registration started (DADF Feed Motor On (CCW)), the Registration Sensor did notturn On within the specified time.Initial Actions• Refer to BSD 5.4/5.5.ProcedureExecute Component Control[005-110]. Actuate the DADF Registration Sensor (PL 15.7) withpaper. The display changes.Y NCheck the connections of P/J782 and P/J761. P/J782 and P/J761 are connected cor-rectly.Y NConnect P/J782 and P/J761.Check the wire between /J782 and J761 for an open circuit or a short circuit (BSD 5.4Flag 1/Flag 2). The wire between /J782 and J761 is conducting without an open cir-cuit or a short circuit.Y NRepair the open circuit or short circuit.Measure the voltage between the DADF PWB P761-15 (+) and GND (-) (BSD 5.4Flag 2).The voltage is approx. +5VDC.Y NReplace the DADF PWB (PL 15.3).Measure the voltage between the DADF PWB P761-14 (+) and GND (-) (BSD 5.4 Flag 1).Actuate the DADF Registration Sensor with paper. The voltage changes.Y NReplace the DADF Registration Sensor (PL 15.7).Replace the DADF PWB (PL 15.3).Execute Component Control[005-001]. The DADF Feed Motor (PL 15.9) starts up.Y NCheck the connections of P/J764 and P/J754. P/J764 and P/J754 are connected cor-rectly.Y NConnect P/J764 and P/J754.Check the wire between J764 and J754 for an open circuit or a short circuit (BSD 5.5 Flag1). The wire between J764 and J754 is conducting without an open circuit or a shortcircuit.Y NRepair the open circuit or short circuit.Measure the voltage between the DADF PWB (PL 15.3) P754-1 (+) and GND (-), andbetween P754-7 (+) and GND (-) (BSD 5.5 Flag 1). The voltage is approx. +24VDC.Y NReplace the DADF PWB (PL 15.3).Replace the DADF Feed Motor (PL 15.9). If the problem persists, replace the DADF PWB(PL 15.3).Replace the DADF PWB (PL 15.3).AABB