February, 20082-555WorkCentre 5225, 5230 077-308, 077-309Status Indicator RapsLaunch Version077-308 Left Hand HIGH Interlock Open RAPBSD-ON:1.4The L/H-H Cover is open.Initial Actions• Power OFF/ON• Opening/closing of the IOT L/H-H Cover.ProcedureCheck opening/closing of the IOT L/H-H Cover. The IOT L/H-H Cover can be opened/closed.Y NReinstall the IOT L/H-H Cover.Check the installation of the Exit 2 Interlock Switch. The Exit 2 Interlock Switch is installedcorrectly.Y NInstall the Exit 2 Interlock Switch correctly.Execute Component Control [071-304 Exit 2 Interlock Switch]. Open/close the IOT L/H-HCover. The display changes.Y NCheck the connections of P/J434, P/J116, P606, J606 and SJ1. The P/J434, P/J116,P606, J606 and SJ1 are connected correctly.Y NConnect P/J434, P/J116, P606, J606 and SJ1.Check the wire between J434 and J116 for an open circuit or a short circuit (BSD 1.4 Flag7/Flag 8). The wire between J434 and J116 is conducting without an open circuit ora short circuit.Y NRepair the open circuit or short circuit.Check the conductivity of the Exit 2 Interlock Switch (PL 6.4) between J434-12 and J434-13 (BSD 1.4 Flag 7/Flag 8). The wire between J434-12 and J434-13 is connectingsuccessfully when the IOT L/H-H Cover is closed, and is insulated when the coveris open.Y NReplace the Exit 2 Interlock Switch (PL 6.4).Replace the MCU PWB (PL 9.1).Replace the MCU PWB (PL 9.1).077-309 Left Hand Low Interlock Open RAPBSD-ON:1.4The L/H Lower Cover is open.Initial Actions• Power OFF/ON• Opening/closing the L/H Lower Cover.ProcedureCheck opening/closing of the L/H Lower Cover. The L/H Lower Cover can be opened/closed.Y NReinstall the L/H Lower Cover (PL 2.5).Check the installation of the L/H Lower Cover Interlock Switch. The L/H Lower Cover Inter-lock Switch is installed correctly.Y NInstall the L/H Lower Cover Interlock Switch (PL 2.5) correctly.Execute Component Control [071-302 L/H Lower Cover Interlock Switch]. Open/close the L/HLower Cover. The display changes.Y NCheck the connections of P/J106 and P/J410. P/J106 and P/J410 are connected cor-rectly.Y NConnect P/J106 and P/J410.Check the wire between J106 and J410 for an open circuit or a short circuit (BSD 1.4 Flag1/Flag 2). The wire between J106 and J410 is conducting without an open circuit ora short circuit.Y NRepair the open circuit or short circuit.Check the conductivity of the L/H Lower Cover Interlock Switch (PL 2.5) between J410-11and J410-12 (BSD 1.4 Flag 1/Flag 2). The wire between J410-11 and J410-12 is con-necting successfully when the L/H Lower Cover is closed, and is insulated whenthe cover is open.Y NReplace the L/H Lower Cover Interlock Switch (PL 2.5).Replace the MCU PWB (PL 9.1).Replace the MCU PWB (PL 9.1).