February, 20082-69WorkCentre 5225, 5230 005-196Status Indicator RapsLaunch Version005-196 CVT Size Mismatch JAM (No Mix) RAPThe second and subsequent documents are different size to the first document.Initial Actions• Refer to BSD 5.1.ProcedureExecute Component Control[005-221]. Actuate the DADF Tray Size 1 Sensor with paper. Thedisplay changes.Y NCheck the connections of P/J771 and P/J759. P/J771 and P/J759 are connected cor-rectly.Y NConnect P/J771 and P/J759.Check the wire between J771 and J759 for an open circuit or a short circuit (BSD 5.1 Flag1/Flag 2). The wire between J771 and J759 is conducting without an open circuit ora short circuit.Y NRepair the open circuit or short circuit.Measure the voltage between the DADF PWB P759-3 (+) and GND (-) (BSD 5.1 Flag 2).The voltage is approx. +5VDC.Y NReplace the DADF PWB (PL 15.3).Measure the voltage between the DADF PWB P759-2 (+) and GND (-) (BSD 5.1 Flag 1).Actuate the DADF Tray Size 1 Sensor with paper. The voltage changes.Y NReplace the DADF Tray Size 1 Sensor (PL 15.10).Replace the DADF PWB (PL 15.3).Execute Component Control[005-222]. Actuate the DADF Tray Size 2 Sensor with paper. Thedisplay changes.Y NCheck the connections of P/J772 and P/J759. P/J772 and P/J759 are connected cor-rectly.Y NConnect P/J772 and P/J759.Check the wire between J772 and J759 for an open circuit or a short circuit (BSD 5.1 Flag3/Flag 4). The wire between J772 and J759 is conducting without an open circuit ora short circuit.Y NRepair the open circuit or short circuit.Measure the voltage between the DADF PWB P759-6 (+) and GND (-) (BSD 5.1 Flag 4).The voltage is approx. +5VDC.Y NReplace the DADF PWB (PL 15.3).Measure the voltage between the DADF PWB P759-5 (+) and GND (-) (BSD 5.1 Flag 3).Actuate the DADF Tray Size 2 Sensor with paper. The voltage changes.Y NReplace the DADF Tray Size 2 Sensor (PL 15.10).Replace the DADF PWB (PL 15.3).Replace the DADF PWB (PL 15.3).AABB