February, 20081-6 WorkCentre 5225, 5230Detailed Maintenance ActivitiesLaunch VersionService Call ProceduresDetailed Maintenance Activities (HFSI)Procedure1. Access Diagnostic Routines.a. Enter UI Diagnostics (Entering UI Diagnostics in UI Diagnostic Mode).b. Access Diagnostic Routines (Accessing Diagnostic Routines in UI DiagnosticMode).2. Select NVM Read/Write.3. Refer to Table 1 and enter a counter number for any High Frequency Service Item (HFSI)counters to be checked. Use the customer's output volume numbers to help determinewhich HFSI components should be serviced. Consider components near threshold ascandidates for service.4. Refer to Cleaning Procedures for detailed cleaning instructions.Table 1 High Frequency Service ItemsCounter NameThres-hold Service Action to be performed954-800 Tray 1 Feed counter 300K Replace the Feed Roll, Retard Roll, NudgerRoll.954-801 Tray 2 Feed counter 300K Replace the Feed Roll, Retard Roll, NudgerRoll.954-802 Tray 3 Feed counter 300K Replace the Feed Roll, Retard Roll, NudgerRoll.954-803 MSI Feed counter 50K Replace the Feed Roll, Retard Pad.954-804(7232/42)HCF Feed/Retard/Nudger300K Replace the Feed Roll, Retard Pad andNudger Roll954-824 IBT Belt counter 480K Replace the IBT Assembly.954-825 IBT Cleaner counter 100K Replace the IBT Cleaner.954-826 2nd BTR Counter 150K Replace the Bias Transfer Roll.954-830 K Developer Counter 420K Replace the K Developer.954-831 Y Developer Counter 420K Replace the Y Developer.954-832 M Developer Counter 420K Replace the M Developer.954-833 C Developer Counter 420K Replace the C Developer.954-837 Xero Drum Counter 10M Replace the Xero Drum Assembly.954-842 Fuser Counter 10M Replace the Fuser Assembly.954-850 Deodorant Filter 5M Replace the Deodorant Filter.956-802 Lamp Scan Counter 6000K Replace the Exposure Lamp.956-803 Exposure Lamp TimeCounter7200K Replace the Exposure Lamp.956-804 Exposure Lamp OnCounter6000K Replace the Exposure Lamp.955-806 CVT Feed Counter 200K Replace the Document Nudger Roll, FeedRoll, Retard Roll, Registration Roll.955-807 Simplex Feed Counter 912K Replace the Document Nudger Roll, FeedRoll, Retard Roll, Registration Roll.955-808 Duplex Feed Counter 912K Replace the Document Nudger Roll, FeedRoll, Retard Roll, Registration Roll.955-810 Platen InterlockCounter260K Replace the Platen Interlock Switch.955-829 Inverter Solenoid OnCounter500K Replace the Inverter Solenoid.Table 1 High Frequency Service ItemsCounter NameThres-hold Service Action to be performed