5.10 o: Operator Related SettingsThese parameters control the various functions, features, and display of the digital operator.u o1: Digital Operator Display SelectionThese parameters determine the data display on the digital operator.n o1-01: Drive Mode Unit Monitor SelectionThe frequency reference display appears when the drive is powered up. Pressing the up arrow key will display the followingdata: frequency reference → rotational direction → output frequency → output current → o1-01 selection.Parameter o1-01 selects the content of the last monitor in this sequence.No. Name Setting Range Defaulto1-01 Drive Mode Unit Monitor Selection 104 to 809 106 (U1-06)n o1-02: User Monitor Selection after Power UpSelects which monitor parameter is displayed upon power up. Refer to U: Monitor Parameters on page 286 for a list ofmonitors.No. Name Setting Range Defaulto1-02 User Monitor Selection after Power Up 1 to 5 1Setting 1: Frequency Reference (U1-01)Setting 2: Motor DirectionSetting 3: Output Frequency (U1-02)Setting 4: Output Current (U1-03)Setting 5: User-selected Monitor (Set by o1-01)n o1-03: Digital Operator Display SelectionSets the units used to display the frequency reference and output frequency. Set o1-03 to 3 for user-set units before settingparameters o1-10 and o1-11.No. Name Setting Range Defaulto1-03 Digital Operator Display Selection 0 to 3 0Setting 0: 0.01 Hz unitsSetting 1: 0.01% units (100% = max. output frequency)Setting 2: r/min units (calculated by the max output frequency and the no. of motor poles)Setting 3: User-set units (set by o1-09, o1-10, o1-11)Set the value used for the maximum frequency reference to o1-10. Set the placement of the decimal point in this number too1-11.For example, to have the maximum output frequency displayed as “100.00”, set o1-10 to 1000 and o1-11 to 2 (i.e., 1000 with2 decimal points).Note: 1. Parameter o1-03 allows the programmer to change the units used in the following parameters and monitors:U1-01: frequency referenceU1-02: output frequencyU1-16: output frequency after softstarter (accel/decel ramp generator)d1-01 to d1-17: frequency references2. Setting o1-03 to 2 requires entering the number of motor poles to E2-04.5.10 o: Operator Related SettingsYASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual 2675 Parameter Details