No.(Addr.Hex) Name Description Values Paged1-17(292) Jog Frequency ReferenceSets the Jog frequency reference. Setting units are determined by parametero1-03. Default: 6.00 HzMin.: 0.00Max.: 400.00 <1> 182<1> Range upper limit is determined by parameters d2-01, Frequency Reference Upper Limit, and E1-04, Maximum Output Frequency.u d2: Frequency Upper/Lower LimitsNo.(Addr.Hex.) Name Description Setting Paged2-01(289) Frequency Reference UpperLimitSets the frequency reference upper limit as a percentage of the maximumoutput frequency. Default: 100.0%Min.: 0.0Max.: 110.0 184d2-02(28A) Frequency Reference LowerLimitSets the frequency reference lower limit as a percentage of the maximumoutput frequency. Default: 0.0%Min.: 0.0Max.: 110.0 184d2-03(293) Master Speed ReferenceLower LimitSets the lower limit for frequency references from analog inputs as apercentage of the maximum output frequency. Default: 0.0%Min.: 0.0Max.: 110.0 185u d3: Jump FrequencyNo.(Addr.Hex) Name Description Values Paged3-01(294) Jump Frequency 1Eliminates problems with resonant vibration of the motor/machine byavoiding continuous operation in predefined frequency ranges. The driveaccelerates and decelerates the motor through the prohibited frequency ranges.Setting 0.0 disables this function.Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.Default: 0.0 HzMin.: 0.0Max.: 400.0 185d3-02(295) Jump Frequency 2Eliminates problems with resonant vibration of the motor/machine byavoiding continuous operation in predefined frequency ranges. The driveaccelerates and decelerates the motor through the prohibited frequency ranges.Setting 0.0 disables this function.Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.Default: 0.0 HzMin.: 0.0Max.: 400.0 185d3-03(296) Jump Frequency 3Eliminates problems with resonant vibration of the motor/machine byavoiding continuous operation in predefined frequency ranges. The driveaccelerates and decelerates the motor through the prohibited frequency ranges.Setting 0.0 disables this function.Parameters must be set so that d3-01 ≥ d3-02 ≥ d3-03.Default: 0.0 HzMin.: 0.0Max.: 400.0 185d3-04(297) Jump Frequency Width Sets the dead-band width around each selected prohibited frequency referencepoint. Default: 1.0 HzMin.: 0.0Max.: 20.0 185u d4: Frequency Reference Hold and Up/Down 2 FunctionNo.(Addr.Hex) Name Description Values Paged4-01(298) Frequency Reference HoldFunction Selection0: Disabled. Drive starts from zero when the power is switched on.1: Enabled. At power up, the drive starts the motor at the Hold frequency thatwas saved.Default: 0Range: 0, 1 186d4-03(2AA) Frequency Reference BiasStep (Up/Down 2)Sets the bias added to the frequency reference when the Up 2 and Down 2digital inputs are enabled (H1-oo = 75, 76). Default: 0.00 HzMin.: 0.00Max.: 99.99 187d4-04(2AB) Frequency Reference BiasAccel/Decel (Up/Down 2)0: Use selected accel/decel time.1: Use accel/decel time 4 (C1-07 and C1-08).Note: The functionality of setting 1 is only accessible viaMEMOBUS/Modbus communication.Default: 0Range: 0, 1 188B.5 d: References444 YASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual