u Three-Phase 600 V Class Drive Models 5A0041 to 5A0099Table A.8 Power Ratings Continued (Three-Phase 600 V Class)Item SpecificationDrive Models 5A0041 5A0052 5A0062 5A0077 5A0099Maximum Applicable Motor Capacity (HP)<1> ND Rating 40 50 60 75 100InputInput Current (A) <2> ND Rating 44 54 66 80 108Rated VoltageRated Frequency Three-phase 500 to 600 Vac 50/60 HzAllowable Voltage Fluctuation -10 (-15) to +10%Allowable Frequency Fluctuation ±5%Input Power (kVA) ND Rating 50 62 75 91 123OutputRated Output Capacity (kVA) <3> ND Rating <4> 41 52 62 77 99Rated Output Current (A) ND Rating <4> 41 52 62 77 99Overload Tolerance ND Rating: 120% of rated output current for 60 s(Derating may be required for applications that start and stop frequently)Carrier Frequency User-adjustable between 1 and 10 kHz <4>User-adjustablebetween 1 and8 kHz <4>Maximum Output Voltage (V) Three-phase 500 to 600 V (proportional to input voltage)Maximum Output Frequency (Hz) 400 Hz (user-set)<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater thanthe motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiringconnections, and power supply impedance.<3> Rated motor capacity is calculated with a rated output voltage of 575 V.<4> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settingsraise the carrier frequency and require current derating.A.1 Power RatingsYASKAWA SIEP YAIP1U 01C AC Drive - P1000 Technical Manual 401A Specifications