TRBLSHTG Troubleshooting9-61 69J3D11Self-diagnosis 9Diagnosing the electronic controlsystem1. Connect the special tools to the outboardmotor as shown.NOTE:When performing this diagnosis, all of theelectrical wires must be properly connected.2. Start the engine and let it idle.3. Check the flash pattern of the diagnosticindicator to determine if there are anymalfunctions.• Normal condition(no defective part or irregular process-ing is found)• Single flash is given every 4.95 sec-onds.a: Light on, 0.33 secondb: Light off, 4.95 seconds• Trouble code indicationExample: The illustration indicatescode number 23.a: Light on, 0.33 secondb: Light off, 4.95 secondsb: Light off, 0.33 secondd: Light off, 1.65 seconds4. If a flash pattern listed in the diagnosiscode chart is displayed, check the mal-functioning part according to the flashpattern.NOTE:When more than one problem is detected,the light of the diagnostic tester flashes in thepattern of the lowest numbered problem.After that problem is corrected, the lightflashes in the pattern of the next lowest num-bered problem. This continues until all of theproblems are detected and corrected.Diagnostic flash indicator 4 1:90890-06795Diagnostic flash adaptor 2:90890-06794S69J9015L/W, L/WR/B, W/B, BÉ