Lead Inspection CheckerOCR Type A23010 ā 910.3 Set the Judgment Conditions10.3 Set the Judgment ConditionsYou can set judgment conditions for the number of leads, lead width, and lead pitch.4. Width Judgment <510.9, 0.0>5. Pitch Judgment <510.9, 0.0>3. Detect Judgment 128Detect JudgmentProduces an OK result if the number of leads detected matches the setting.Width JudgmentSet maximum and minimum limits for the width of the leads. An OK result is producedif the width is between these limits. Perform an inspection on a good article to obtainthe width value (use the Result item to verify the value) and use this value as an aid insetting the limits (refer to the following page).Pitch JudgmentSet maximum and minimum limits for the lead pitch. An OK result is produced if the pitchis between these limits. Perform an inspection on a good article to obtain the pitch value(use the Result item to verify the value) and use this value as an aid in setting the limits(refer to the following page).