Communications (Serial and Parallel) OCR Type A23016 − 4816.8 Template (Smart matching) Re−registration16.8.4 Notes Regarding Execution Order for Re− registrationSetting position (Re−registration Area Display: No)Procedure:1. Specify the template number for performing re−registration, and input templatere−registration input signal IN8.2. READY signal goes OFF, and re−registration is executed.3. When re−registration is complete, the READY signal goes on.Setting position (Re−registration Area Display: Yes)Procedure:1. Specify the template number for performing re−registration, and input templatere−registration input signal IN8.2. READY signal goes off, and the re−registration area is displayed.3. Input template re−registration input signal IN8 again.4. When re−registration is complete, the READY signal goes on.Execution position (Re−registration Area Display: No)Procedure:1. Specify the template number for performing re−registration, and input templatere−registration input signal IN8.2. READY signal goes off, and the specified smart matching checker isexecuted.3. Re−registration is executed at the position detected in step 2.4. When re−registration is complete, the READY signal goes on.Execution position (Re−registration Area Display: Yes)Procedure:1. Specify the template number for performing re−registration, and input templatere−registration input signal IN8.2. READY signal goes off, and the specified smart matching checker isexecuted.3. Re−registration is executed at the position detected in step 2.4. Input template re−registration input signal IN8 again.5. When re−registration is complete, the READY signal goes on.