Inspection Results and OutputOCR Type A23013 − 3113.5 SpreadsheetsNoteThe number of scans is the total number of starts on the producttype being displayed. The number of OK and NG outputs willcount the data after the checker item is designated.Consequently, the “OK count” and the “NG count” will notnecessarily equal the “Total scan times”. In addition, if the resultis ERR, only the number of errors is counted, and the NG data isnot updated.Spreadsheets can be operated for each product type.The data is cleared to zero when the type is switched or thepower is switched off.You can perform numerical calculations on the final data. The markings for numericaloperations in spreadsheets are as follows:Symbol No. Mode Content1 0 No. of scansQS 1 to 40 1 OK count1 to 40 2 NG count