Inspection Results and Output OCR Type A23013 − 3213.6 Data Monitor13.6 Data MonitorThe Data Monitor function displays the results of numerical calculations and judgmentoutputs in a list. It is also possible to change the maximum and minimum values for thenumerical calculations to be displayed.You can register up to 20 items (10 items/page x 2 pages) with titles (of up to 8characters/symbols). Use 3. Data Monitor to set the items to be displayed, then usethe Menu Setting item in 1. Type to set the Screen Display to Data Monitor.13.6.1 The Data Monitor Display− The inspection result values are displayed with their titles.Up to 10 items can be displayed on each page.Turn pageTYPE [ 1] :Page 1 ← : Hide → : NextWIDTH1 0 NGHIGHT 0 NGTOTAL OKTitle (8 characters)Data display(10 items per page)Numerical calculation judgment resultNumerical calculation result(up to 6 digits)Press Next to change the screen and display the next 10 items.