Communications (Serial and Parallel)OCR Type A23016 − 5916.11 Computer Link2 Product type switchingPLCReady OFFREADY ONReady ONTYPEReady ONOutputs the Typesignal (parallel)after confirmingthat Ready is on.Reads the producttype no. from thespecified dataregister.ResponseProduct type No.to switch toImagecheckerRequest the producttype No. to switchto.Execute theproduct typeswitch.If the specified data register number is out of range, the following command is returnedby the PLC. In this case, communication stops, the Error signal is output, and Readygoes on.Response: %EE!6103BCCIf product type switching is not possible, the Error signal is output and Ready goes on.ONONONT1OFFOFFOFFT2 T2T1Ready signal /READYError signal /ERRORType switch execution signal/TYPET1: TYPE signal width (1ms min.)T2: Response time with respect to the TYPE signal (within 1ms).