Communications (Serial and Parallel)OCR Type A23016 − 1916.4 Inspection Execution and Result Output Procedures16.4 Inspection Execution and Result Output ProceduresThis section explains how to initiate an inspection and output results usingcommunications.16.4.1 Items related to serial/parallel communicationsInput Parallel SerialItemInputoroutputDetails I/O terminal Ref.page Command Ref.pageInspectionpreparationscompleteOutputInspection preparationscomplete(waiting for the next startsignal)RDY (Ready) signalon 16 − 22Input Specific substitutionformula not executedSTA(Start) 16 − 22 %S CR 16 − 20StartinspectionInput Specific substitutionformula executedACK + STA (Start)signal(Hold ACK until RDYgoes off)16 − 22 %P CR 16 − 20InputRe−inspect(image capture: notexecuted)%RCR 16 − 20ImagecapturecompleteOutput Image capture onlycompleteREN(REND) 16 − 27 %RCR 16 − 20Output Inspection complete(before data output) %E CR 16 − 20OutputinspectiondataOutput Judgment outputD1 to D8(for D9 and afterhandshake is ACK,and STROB signal isneeded)16 − 25 Example002148030912 CR16 − 21Output Numerical dataD1 to D8(handshake is ACK,and STROB signal isneeded)16 − 25Ror21,4803,912 CR etc.16 − 21