Communications (Serial and Parallel) OCR Type A23016 − 2616.4 Inspection Execution and Result Output ProceduresNotesTo output judgment results, set Environment − Parallel Output− Judgment to “Out” (even with this setting, zeros are outputonce).When outputting numerical calculation results, setEnvironment − Parallel Output − Numerical Calc. to “Out”(even with this setting, if there are no numerical calculationsset, the data will be output once as zeros, regardless of thedata width).For judgment output, handshaking is performed until the datahas been output from the last specified external outputregister (JD).For numerical calculations, CA registers that have not beenset, and CA registers that perform output control are skipped(not output).The output data length for numerical calculation results canbe set separately for each of 8 groups, CA01 to CA04, CA05 toCA08, CA09 to CA12, CA13 to CA16, CA17 to CA20, CA21 toCA24, CA25 to CA28, and CA29 to CA32.The numerical range that can be handled by each of thesedata lengths is as follows (if a number outside of the range isoutput, the overflow flag goes on).8 bits: 0 to 25516 bits: 0 to 6553532 bits: −2147483648 to 2147483647