Communications (Serial and Parallel) OCR Type A23016 − 1216.2 Communication Settings16.2.5 Serial Output Settings (Computer Link)Select the data, signals and format for performing serial communication usingComputer Link.431. Type No. RegisterSpecify the PLC register number in the range 0 to 9999.When the TYPE signal is input, the product type is switched to thenumber that corresponds to the value stored in the register numberspecified here.Example:If the product type register setting is 1, and the value stored in registerDT1 is 5, then, when the TYPE signal is input, the product type will beswitched to No. 5.432. Top Data RegisterSet the top register number for use when outputting data to PLC. Thesetting range is 0 to 9999.433. TimeoutSet the maximum time to wait for a response after outputting data to thePLC, or after requesting a product type switching number.434. OutputSet the bit length for the output data to either 16 or 32 bits.435. Output Char.Set the maximum number of characters that can be recognized per achecker.436. Numerical CalculationSet whether or not to output the numerical calculation results.437. JudgmentSet whether or not to output the judgment results.438. Char. Recog.Set whether or not to output the recognized string.439. PLC TypeSet the PLC type (Panasonic Industrial Devices SUNX Co., Ltd. PLC−FP seriesand models from some other manufacturers are available.)