Communications (Serial and Parallel)OCR Type A23016 − 5516.10 Referencing and Changing the Maximum and Minimum Limits for Numerical Calculations16.10.2 Referencing Maximum/Minimum Limits%F??Register No. (2 digits)%F01 CR to %F32 CR are used to reference the maximum and minimum values for anumerical calculation.When the maximum and minimum values for a numerical calculation are referencednormally, %F followed by the Register No., Minimum value and Maximum value(delimited with commas), and CR are returned as the response. If a Register No. thathas not been set is specified, the maximum and minimum values for the numericalcalculation will not be referenced normally, and %Z CR is returned as the response.16.10.3 Changing the Maximum and Minimum Limits%N??,n,n CRRegister No. (2 digits)Minimum value (– 2147483648 to 2147483648)Maximum value (– 2147483648 to 2147483648)To change the maximum and minimum limits, send %N followed by the minimum limit,and the maximum limit and CR (delimited by commas).When the maximum and minimum values for a numerical calculation are changednormally, %N followed by the Register No., Minimum value and Maximum value(delimited with commas), and CR are returned as the response.