Communications (Serial and Parallel)OCR Type A23016 − 4916.8 Template (Smart matching) Re−registrationAdjustment position (Re−registration Area Display: No)Procedure:1. Specify the template number for performing re−registration, and input templatere−registration input signal IN8.2. READY signal goes off, and the position adjustment checker registered for theposition adjustment group No. of the specified smart matching checker isexecuted, and the smart matching is adjusted.3. Re−registration is executed at the position of the smart matching that wasadjusted in step 2., and the positional relationship between the first registeredsearch area and the template is maintained.4. When re−registration is complete, the READY signal goes on.Adjustment position (Re−registration Area Display: Yes)Procedure:1. Specify the template number for performing re−registration, and input templatere−registration input signal IN8.2. READY signal goes off, and the position adjustment checker registered for theposition adjustment group No. of the specified smart matching checker isexecuted, and the smart matching is adjusted.3. Re−registration is executed at the position of the smart matching that wasadjusted in step 2., and the template position (whose positional relationshipwith the first registered search area has been maintained) is displayed as there−registration area.4. Input template re−registration input signal IN8 again.5. Re−registration is executed at the position of step 3., and when it is complete,the READY signal goes on.NotesTemplates other than those of the current type cannot bere−registered.Perform re−registration when the main screen READY signalis in the on state.The template is registered as a gray image, regardless of theimage displayed on the monitor.Registration is possible if you capture a new image when themonitor display image is a “Thru” image, but if it is a “Mem”image, re−registration is executed using the currentlydisplayed image.The re−registered template will be lost if the power is switchedoff. If you wish to keep it, perform a data save beforeswitching the power off.