Communications (Serial and Parallel) OCR Type A23016 − 4616.8 Template (Smart matching) Re−registrationSetting Position:Re−registration Area Display: No or YesExecution Position, Adjustment Position:Re−registration Area Display: NoArea display when set to “Yes” (first IN8 input)Error exampleOFFOFFONOFFONError signal /ERRORONTemplate No.Ready signalTemplatere−registrationinput/IN8/READY/IN1 to /IN2The ERROR signal output conditions are as follows:Setting position− You specified a non−existent checker.− The specified checker number is set for an image from a camera other than that setfor the capture camera.− The capacity was exceeded.− You attempted to register an image without features.Execution position− You specified a non−existent checker.− The specified checker number is set for an image from a camera other than that setfor the capture camera.− The result of number of detected objects from execution of the smart matchingchecker was 0.Adjustment position− You specified a non−existent checker.− The specified checker number is set for an image from a camera other than that setfor the capture camera.− Execution of position adjustment resulted in part of the template area protruding offthe screen.