Communications (Serial and Parallel) OCR Type A23016 − 4216.8 Template (Smart matching) Re−registration16.8.2 Communication SettingsSelect [Communication] → [Parallel Output] → [Setting Template].44. Parallel Output441.Handshake Yes442.Reset Cond. Latch444.Disp. Img. Change Details Mode443.Setting Template NoSetting TemplateSet. Pos.NoExe. Pos.Adj. Pos.Set the following:− Whether or not to perform re−registration.− The execution method.Setting positionRe−registration is executed at the position set for the template area.Because position adjustment and smart matching are not executed, re−registration isnot performed if the object or template image positions have moved.Execution positionRe−registration is executed at the detected position after smart matching is executed.Because position adjustment is not executed, re−registration is not performed if theobject position has moved.If the template could not be detected when smart matching was executed (due to thetemplate image and re−registration image being different etc.), an error is generatedand re−registration is cancelled.Adjustment positionPosition adjustment is executed, and re−registration is performed after the smartmatching is adjusted. Smart matching is not executed, so the positional correlationbetween the search area when the area was set and the template area is maintained,and the image at this position is re−registered as the template.