Inspection Results and Output OCR Type A23013 − 2013.4 Judgment Output13.4 Judgment Output13.4.1 About Judgment OutputThe results of judgments performed on checkers and numerical calculationprogrammes can be communicated to other devices.The conditions for output are described here.The image cannot be changed once you enter the Judgment menu, so if you wish tobe able to see a particular image during Judgment setup, change to the required imagebefore entering the Judgment menu.TYPE[ 1] :A:Start B:−−−−−−−− C:Esc.[9] JUDGMENTProgram Jud.Time: 0.0msJD02= −−JD03= −−JD04= −−JD05= −−JD06= −−JD07= −−JD08= −−(3)(1) (2)JD01= −−1. Output register No.Specify which output register the results of judgment are output from.There are two different types of judgment output registers; internal judgmentregisters (R) and registers for external output (D). You can set up to 32 registersfor the A220, and up to 8 registers for the A100. Only 8 registers can be shown onscreen at a time, but the screen can be scrolled with the cursor lever.NoteThe judgment results set in JR01 to JR32 (JR01 to JR08 for theA100) are not externally output.2. JudgmentDisplays the judgment result for the set judgment conditions (OK, NG, or ER).3. Judgment conditions programmeDisplays the judgment conditions programme that has been set. The judgmentconditions programme can be up to 55 characters in length.