Communications (Serial and Parallel) OCR Type A23016 − 616.1 Communications FunctionInput Parallel SerialItemInputoroutputDetails I/O terminal Ref.page Command Ref.pageRe−registerSmartMatchingInputSpecification of SmartMatching checker No.+re−registration timingIN1 to 2(Smart Matchingchecker No. + IN8)(re−registration timing)16 − 43MatchingcheckerOutput Switching completeConfirm by RDY(READY) signal off toon transition.16 − 44Input Refer to max. andmin. limits%F??CR(??=01to32) 16 − 54NumericalOutput Response to refer-ence%F??,n,nCR(??=01to32) 16 − 54NumericalcalculationInput Change max. andmin. limits%N??,n,nCR(??=01to32) 16 − 54Output Change complete %N??,n,nCR(??=01to32) 16 − 54SwitchInputSpecification ofProduct No. to switchto + switching timingIN1 to 5 + TYPE 16 − 31 %X?? CR(??=01to32) 16 − 29SwitchproductOutput Switching completeConfirm by RDY(READY) signal off toon transition.16 − 31 %Y?? CR(??=01to32) 16 − 29Easy mode(switching between Aand B)IN7 16 − 52SwitchcameraInput Detailed mode(A or B, Thru orMemory)IN1 to 2(Image specification +IN7)(switching timing)16 − 52 %I?CR(??=0to3) 16 − 51Output Switching completeConfirm by RDY(READY) signal off toon transition.16 − 52%ICR(for switching withDetailed mode only)16 − 51SpreadsheetsInput Spreadsheet reset %QCR 13 − 30SpreadsheetsOutput Reset complete %QCR 13 − 30