BRKT Bracket unit7-37 67C3K11Checking the brush holder andbrush1. Check the brush holder assembly forcontinuity. Replace the PTT motor base ifout of specification.NOTE:The brush holder and circuit breaker cannotbe removed from the PTT motor base; ifeither part is damaged, replace the PTTmotor base.2. Measure the length of each brush.Replace the brushes if below specifica-tion.Assembling the PTT motorCAUTION:• Do not reuse the oil seal and O-rings,always replace them with new ones.• Do not allow grease or oil to contact thecommutator of the armature.1. Install a new oil seal into the PTT motorbase as shown.2. Install the brush springs 3, brush (shortlead) 4, brush (long lead) 5, and brushholder screws 6 to the PTT motor base7 as shown.PTT motor base continuityChecking point ContinuityTerminal 1 – 3 (L)Terminal 2 – 4 (G) YesFor all terminal combinationsnot listed above. NoS67C706912 1234LGG43LMotor brush standard length:6.0 mm (0.24 in)Wear limit a: 3.0 mm (0.12 in)Driver rod L3 1: 90890-06652Needle bearing attachment 2:90890-06615Brush lead length: a > bS67C707121S67C70725 43 3676 a b