ELEC Electrical system– +8-27 67C3K113. Check the Rectifier Regulator for conti-nuity. Replace if out of specification.NOTE:The voltage values given in the table are forreference only. If voltage is produced, thereis continuity, and, if there is an overload,there is no continuity. Refer to the table todetermine if there should or should not becontinuity and replace the Rectifier Regulatorif out of specification.NOTE:Be sure to set the measurement range a,and display the mark b by pushing the“SHIFT” switch when checking the RectifierRegulator continuity.OL: Indicates an overloadS67C80605R3Y16BGy4Y2Y24Y13GyR5B6S6S18360abRectifier Regulator continuity(testing diode)Tester lead Display value (V)(reference data)Conti-nuity+ -Y1 3 R 5 0.447 YesY1 3 B 6 1.503 YesY1 3 Y2 4 OL NoY2 4 R 5 0.439 YesY2 4 B 6 1.502 YesY2 4 Y1 3 OL NoB 6 R 5 0.416 YesB 6 Y1 3 OL NoB 6 Y2 4 OL NoR 5 B 6 OL NoR 5 Y1 3 OL NoR 5 Y2 4 OL No