Required tools and equipmentNoteArticle numberEquipmentContent is defined in sectionStandard toolkit on page 629.-Standard toolkitDeciding calibration routineDecide which calibration routine to be used, based on the information in the table.Depending on which routine is chosen, action might be required prior to beginningthe repair work of the robot, see the table.NoteActionDecide which calibration routine to use forcalibrating the robot.• Reference calibration. External cablepackages (DressPack) and tools canstay fitted on the robot.• Fine calibration. All external cablepackages (DressPack) and toolsmust be removed from the robot.1Follow the instructions given in the refer-ence calibration routine on the FlexPendantto create reference values.If the robot is to be calibrated with refer-ence calibration:Find previous reference values for the axisor create new reference values. These val-ues are to be used after the repair proced-ure is completed, for calibration of the ro-bot.Creating new values requires possibility tomove the robot.Read more about reference calibration forAxis Calibration in Reference calibrationroutine on page 594.If no previous reference values exist, andno new reference values can be created,then reference calibration is not possible.If the robot is to be calibrated with finecalibration:Remove all external cable packages(DressPack) and tools from the robot.Removing the turning discUse these procedures to remove the turning disc.Preparations before removing the turning discNoteActionRun the robot to a position most comfortable forthe removal of the turning disc.1DANGERTurn off all:• electric power supply• hydraulic pressure supply• air pressure supplyto the robot, before entering the safeguardedspace.2Remove any equipment fitted to the turning disc.3Continues on next pageProduct manual - IRB 6720 2873HAC085697-001 Revision: C© Copyright 2023 ABB. All rights reserved.5 Repair5.5.2 Replacing the turning discContinued