Chapter 55-509) Secure the cable fixing [1] that was temporarily fixed in place in step6) by tightening the 2 screws [2] from the opening in the side plate.(front)F-5-168(rear)F-5-16910) Detach the mirror positioning tool.11) Reverse steps 1) through 4).5.4.17.3 Removing the Scanner System Drive Cable0008-8050/ iR8070Obtain the following before starting to replace the scanner drive cable:- mirror positioning tool (FY9-3009)1) Remove the ADF.2) Remove the copyboard glass.3) Remove the reader left cover and the reader front cover.4) Remove the motor cover.5) Remove the five screws [1], and detach the PCB base [2].F-5-1706) Remove the screw [1], and detach the ADF base (left) [2]; then,remove the three screws [3], and detach the copyboard sensor base[4].F-5-1717) Remove the 15 screws [1], and remove the two screws [2]; then,detach the reader upper frame [3].F-5-1728) Remove the two cable fixing screws [2] of the No. 1 mirror base [1].9) Remove the two springs [3] used to secure the cable in place.10) Remove the cable fixing plate [4] and each pulley cable.F-5-1735.4.17.4 Removing the No. 1 Mirror Case Flexible Cable0007-1759iR105i/iR105+ / iR9070Do not disconnect the connector (connected to the No. 1 mirror base) ofthe flexible cable unless you are replacing the No. 1 mirror base. (Cleanthe mirror without detaching the cable.)1) Remove the right glass retainer. (2 screws)2) Remove the copyboard.3) Move the No. 1 mirror base [1] to the center.[2][2] [1][1] [2][2][1][2][1] [2][4][3][1][1] [1][3][2][2][3][4][1][2]