Chapter 1616-1516.2.2 Error Code Detail0008-8491/ iR8070T-16-50002 The lock signal is detected for 5 sec or morealthough the separation heat discharging fan isbeing driven.- Check if there is no foreign material in the rotationassembly of the separation heat discharging fan.- Check if the connector (J1112) of the reader controllerPCB is mounted properly.- Replace the separation heat discharging fan.- Replace the reader controller PCB.E820 The rotation of the drum fan is faulty.0000 The lock signal is detected for 5 sec or morealthough the drum fan is being driven.- Check if there is no foreign material in the rotationassembly of the drum fan.- Check if the connector (J512) of the DC controllerPCB is mounted properly.- Replace the drum fan.- Replace the DC controller PCB.E823 The rotation of the pre-transfer charging assembly fan is faulty.0000 The lock signal is detected for 5 sec or morealthough the pre-transfer charging assemblyfan is being driven.- Check if there is no foreign material in the rotationassembly of the pre-transfer charging assembly fan.- Check if the connector (J504) of the DC controllerPCB is mounted properly.- Replace the pre-transfer charging assembly fan.- Replace the DC controller PCB.E830 The rotation of the separation fan is faulty.0000 The lock signal is detected for 5 sec or morealthough the separation cooling fan is beingdriven.- Check if there is no foreign material in the rotationassembly of the separation cooling fan.- Check if the connector (J509) of the DC controllerPCB is mounted properly.- Replace the separation cooling fan.- Replace the DC controller PCB.Code Cause RemedyE000 The temperature of the fixing assembly is abnormally high.0000 When the main power switch is turned on, thereading of the main thermistor does not reach70 deg C within 3 min 30 sec.- Check if the main thermistor is mounted properly andalso check if there is no contamination.- Replace the main thermistor.- Replace the AC driver PCB.- Replace the DC controller PCB.CautionYou must clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).0010 The power is turned off and then on withoutclearing the error.- Clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).E001 The over-rising in temperature of the fixing assembly is detected.0001 The hardware port detects a fault. - Replace the AC driver PCB.- Replace the DC controller PCB.CautionYou must clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).0002 Either the main thermistor or the subthermistor detects 230 deg C or higher for 2sec.- Check if the main thermistor and the sub thermistor aremounted properly.- Replace the main thermistor or the sub thermistor.- Replace the AC driver PCB.- Replace the DC controller PCB.CautionYou must clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).0003 The reading of the main thermistor is higherthan that of the sub thermistor by 50 deg C ormore for 1 sec.Check if the main thermistor and the sub thermistor aremounted properly.- Replace the main thermistor.- Replace the AC driver PCB.- Replace the DC controller PCB.CautionYou must clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).Code Cause Remedy