Chapter 1616-180000 The DC controller PCB detects an overcurrentflowing to the toner feed motor (M6) inside thecartridge for 10 sec or more twice. (In responseto the first detection, it indicates the message"Shake the Toner Case, and Set.")- Check if the connector (J512) of the DC controllerPCB is mounted properly.- Replace the toner feed motor (M6).E032 The counter of the copy data controller or the NE controller is faulty.0000 The copy data controller or the NE controllerare disconnected after they have once beenconnected.- Check if the connecter of the main controller PCB ismounted properly.- Replace the main controller PCB.- Replace the copy data controller or the NE controller.E043 The rotation of the side paper deck main motor is faulty.0000 The PLL lock signal (DMPLK) does not arrivefor 2 sec or more after the side paper deck mainmotor drive signal has been generated.- Check if the connecter (J101, J106) of the side deckdriver PCB is mounted properly.- Replace the side deck main motor.- Replace the side deck driver PCB.- Replace the DC controller PCB.E051 There is an error in the detection of the horizontal registration home position.0001 Departure from home position is not detectedwithin 5 sec during a horizontal registrationhome position search.- Replace the horizontal registration sensor.- Replace the horizontal registration motor.- Check if the manual feed tray open/closed detectingswitch is mounted properly.- Replace the stackless feed driver PCB.- Replace the DC controller PCB.0002 Home position is not detected within 5 secduring a horizontal registration home positionsearch.- Replace the horizontal registration sensor.- Replace the horizontal registration motor.- Check if the manual feed tray open/closed detectingswitch is mounted properly.- Replace the stackless feed driver PCB.- Replace the DC controller PCB.0003 The horizontal registration detectionmovement for the preceding sheet does not endwithin 5 sec at the start of a horizontalregistration search during printing.- Replace the horizontal registration sensor.- Replace the horizontal registration motor.- Check if the manual feed tray open/closed detectingswitch is mounted properly.- Replace the stackless feed driver PCB.- Replace the DC controller PCB.E065 There is an error in the high-voltage output to the transfer charging assembly.0000 An error (leakage) is detected in the high-voltage output to the primary chargingassembly.- Check if the primary charging assembly is mountedproperly and also check if there is no contamination.- Check if the connector (T601, J723, J730) of the HV-DC PCB is mounted properly and also check the wiring.- Replace the HV-DC PCB.E067 There is an error in the high-voltage output.0000 An error is detected in two or more of thefollowing at the same time: the primary highvoltage, pre-transfer high voltage, transferhigh voltage, and separation high voltage. Or,an error (leakage) in the high-voltage output tothe separation charging assembly is detected.- Check if the primary charging assembly, pre-transfercharging assembly, transfer charging assembly andseparation charging assembly are mounted properly.- Check if the connector (J722, J723, J730) of the HV-DC PCB is mounted properly and also check the wiring.- Replace the HV-DC PCB.- Replace the HV-AC PCB.E068 There is an error in the high-voltage output to the separation charging assembly.0000 An error (leakage) to the high-voltage outputto the separation charging assembly isdetected.- Check if the transfer charging assembly and separationcharging assembly are mounted properly.- Check if the connector (J722, J723, J730, J734) of theHV-DC PCB and the connector (J741, J742) of the HV-AC PCB are mounted properly.- Replace the HV-AC PCB.- Replace the separation charging assembly.- Replace the pre-transfer charging assembly.E069 There is an error in the high-voltage output to the transfer charging assembly.0000 An error (leakage) is detected in the high-voltage output to the transfer chargingassembly.- Check if the transfer charging assembly and separationcharging assembly are mounted properly.- Check if the connector (T701, J723, J730) of the HV-DC PCB is mounted properly and also check the wiring.- Replace the HV-DC PCB.- Replace the pre-transfer charging assembly.E100 The BD PCB is faulty.0000 The BD signal does not arrive within 1 secafter the laser drive signal has been generated.Or, the BD signal does not arrive for 1 sec ormore while the laser remains ON.- Check if the BD PCB, laser driver PCB and DCcontroller are connected properly.- Replace the BD PCB.- Replace the laser scanner unit.- Replace the DC controller PCB.E110 The rotation of the laser scanner motor is faulty.Code Cause Remedy