Chapter 1313-2813.3.5 Scheduled Service Items0006-9902iR105i/iR105+ / iR9070Do not use solvents or oils not indicated herein.T-13-2413 Press the leakage breaker testswitch to make sure that thebreaker operates normally.Thereafter,turn off the power switch,and shift the lever to ON position;then, turn on the power switch.Press the test switch whilethe power switch is ON andthe lever [1] of the leakagebreaker is at ON; if normal,the lever should shift to OFFposition to cut off the power(Pay attention to theorientationwhenever replacing thebreaker. If you have replacedthe breaker, be sure to checkits operation).Check to make sure that the grounding is correct; otherwise, leakage may not trigger theleakage breaker.14 Put the test prints in order, andclean up the area around themachine.15 Record the latest counter readings.16 Record the latest counter readings. Record the results of thecheck made on the leakagebreaker in the Service Book.Service intervalUnit Location installation every every Remarks500,000 1,000,000Externals andcontrolsCopyboard glass CleanOzone filter (FM2,FM8, M20)Clean Replace Remove dust from thefilter surface.Dust filter (FM1 (2pc.), FM3, FM10, frontcover, upper frontcover)Clean Remove dust from thefilter surface.Scanner system Scanner wire CheckAdjustCheck only at initial500,000 pages.Scanner rail CleanLubricateUse silicone oilS-20 (FY9-6011)Optical system No. 1 to No. 3 mirrors CleanDust-proof glass CleanReflecting plate CleanStandard white plate CleanPre-transfer exposureLEDClean ReplaceChargingassemblyCharging wire(Primary)Clean Replace If high temperature/humidity, every250,000 pages.Charging wire(Transfer/separation)Clean Replace If high temperature/humidity, every250,000 pages.Charging wire (Pre-transfer)Clean Replace If high temperature/humidity, every250,000 pages.[1]