Chapter 1717-87T-17-92H-PRE-TR Use it to enter an offset value for the pre-transfer high-voltage output of the high-voltage unit.1ޓ-100 to 100If you have replaced the high-voltage unit, be sure to enter the value indicated onthe label attached to the new high-Voltage unit. If you have replaced the DC controllerPCB or cleared the RAM on the DC controller PCB, be sure to enter the value indicatedon the service sheet.The value entered and the value displayed after making the entry may fail tomatch.D-PRE-TR Use it to enter an offset value for the pre-transfer high-voltage output of the DCcontroller PCB.1ޓ-100 to 100If you have replaced the DC controller PCB, be sure to enter the value indicatedon the label attached to the new DC controller PCB.If you have cleared the RAM of the DC controller PCB, be sure to enter the valueindicated on the service sheet.The value entered and the value displayed after making the entry may fail tomatch.D-HV-TR Use it to enter an offset value for the transfer high-voltage output of the DC controllerPCB.1ޓ-100 to 100If you have replaced the DC controller PCB, be sure to enter the value indicatedon the label attached to the new DC controller PCB.If you have cleared the RAM on the DC controller PCB, be sure to enter the valueindicated on the service sheet.The value entered and the value displayed after making the entry may fail tomatch.COPIER > ADJUST > HV-SPSub-item Description LevelSP-N1 Use it to enter an output adjustment value for the separation charging current (forprinting on a single-side print or on the 1st side of a double-sided print using plainpaper).1ޓ0 to 800If you have replaced the DC controller PCB or cleared the RAM on the DCcontroller PCB, be sure to enter the value indicated on the service sheet.SP-N2 Use it to enter an output adjustment value for the separation charging current (forprinting on the 2nd side of a double-sided print using plain paper).1ޓ0 to 800If you have replaced the controller PCB or cleared the RAM of the DCcontroller PCB, be sure to enter the value indicated on the service sheet.HVT-SP Use it to enter an offset value for the separation high-voltage output of the high-voltage unit.1ޓ-100 to 100If you have replaced the high-voltage unit, be sure to enter the value indicatedon the label attached to the new high-voltage unit. If you have cleared the RAM ofthe DC controller PCB, be sure to enter the value indicated on the service sheet.D-HV-SP Use it to enter an offset value for the separation high-voltage output of the DCcontroller PCB.1ޓ-100 to 100If you have replaced the DC controller PCB, be sure to enter the value indicatedon the label attached to the new DC controller PCB.If you have cleared the RAM of the DC controller PCB, be sure to enter the valueindicated on the service sheet.COPIER > ADJUST > HV-TRSub-item Description Level