Chapter 1616-4216.4 Alarm Code16.4.1 Alarm Code0007-0636iR105i/iR105+ / iR9070T-16-19EE Location code ffff Code00 error code 0804 system fan alarm (detail code: 0004)02 reader assembly (scanner) 0003 dust detection small 10004 dust detection small 20005 dust detection small 30006 dust detection small 40007 dust detection small 50008 dust detention small 60009 dust detection small 70010 dust detection large 10011 dust detection large 20012 dust detection large 30013 dust detection large 40014 dust detection large 50015 dust detection large 60016 dust detection large 70017 small position stream reading prohibit0018 large position stream reading prohibit0019 scanner lamp intensity low04 pickup/feeding system 0001 right deck lifter alarm0002 left deck lifter alarm0003 cassette 3 lifter alarm0004 cassette 4 lifter alarm0007 manual feed tray lifter alarm0008 side paper deck lifter alarm0011 right deck retry alarm0012 left deck retry alarm0013 cassette 3 retry alarm0014 cassette 4 retry alarm0017 manual feed retry alarm0018 side paper deck retry alarm30 high-voltage system 0001 primary charging assembly leakage0002 transfer charging assembly leakage0003 separation charging assembly leakage32 potential control system 0001 potential control VD alarm0002 potential control VL alarm33 fan system 0001 delivery assembly curl-reducing fanalarm0005 scanner motor fan alarm0006 developing fan alarm0007 delivery adhesion prevention fan alarm0009 duplex feeding fan alarm0010 stream reading fan alarm61 sorter/finisher stapler system 0001 staple absent62 saddle stitcher system 0001 stitch staple absent