Chapter 1717-70T-17-58T-17-59T-17-60COPIER > ADJUST > CCDSub-item Description LevelMaking CCD- and Shading-Related AdjustmentsIf faulty images are noted after executing COPIER>FUNCTION>CCD>CCD-ADJ, enter the settingsindicated on the service label.SH-TRGT Use it to enter the white level target value for shading correction. 130 to255 1SH-RATIO Use it to enter the data on the white level ratio (standard white paper andstandard white plate) for shading correction. 150 to 300 1EGGN-ST Use it to enter an adjustment value for the edge gain correction start posi-tionfor the CCD. 100 to 250 1EGGN-END Use it to enter an adjustment value for the edge gain correction end positionfor the CCD. 100 to 250 1COPIER > ADJUST > LASERSub-item Description LevelAdjusting the Laser OutputIf you have cleared the RAM on the DC controller PCB, be sure to enter the settings indicated on the servicelabel.PVE-OFST Use it to adjust the position of laser projection.1 -300 to 300- A higher value moves the spot toward the rear.- A smaller value moves the stop to the front.The laser A spot moves in keeping with the laser B spot.LA-DELAY Entering a delay value after laser unit displacement (Matching the laser main scan)1 0 to 4807Enter the delay value peculiar to the unit affixed to the unit at laser unitreplacement.LA-PWR-A Use it to enter the power adjustment value for the laser A.1 0 to 255If you have replaced the laser unit, enter the power adjustment value for the laser Aindicated on the label attached to the unit.LA-PWR-B Use it to enter the power adjustment value for the laser B.1 ޓ0 to 255If you have replaced the laser unit, enter the power adjustment value for the laser Bindicated on the label attached to the unit.DLY-FINE Use it to fine-adjust the displacement of the laser A or laser B. 1 -16 to 16COPIER > ADJUST > DEVELOPSub-item Description LevelDE-DC Use it to enter the DC output value for image formation.1 0 to 600There are cases that the actual input and the indication after input do not match.DE-NO-DC Use it to enter the development DC output value for non-image formation.1 0 to 600There are cases that the actual input and the indication after input do not match.