Chapter 1616-250000 The reading of the main thermistor (TH1) doesnot reach 100 deg C 2 min 30 sec after it hasexceeded 70 deg C.- Check if the connector (J505) of the DC controllerPCB is mounted properly and also check if theconnector of the fixing assembly is mounted properly.- Check the wiring between the thermistor and the DCcontroller.-Check if the main thermistor is mounted properly andalso check if there is no contamination.- Replace the main thermistor.- Replace the fixing heater.- Replace the AC driver PCB.- Replace the DC controller PCB.CautionYou must clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).0001 The reading of the main thermistor does notreach 150 deg C within 2 min 30 sec after it hasexceeded 100 deg C.- Check if the connector (J505) of the DC controllerPCB is mounted properly and also check if theconnector of the fixing assembly is mounted properly.- Check the wiring between the thermistor and the DCcontroller.-Check if the main thermistor is mounted properly andalso check if there is no contamination.- Replace the main thermistor.- Replace the fixing heater.- Replace the AC driver PCB.- Replace the DC controller PCB.CautionYou must clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).0010 The power has been turned off and then onwithout clearing the error.- Clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).E003 The fixing temperature is too low after a standby state.0000 The reading of the main thermistor is 70 deg Cor lower for 2 sec or more after it has reached100 deg C.- Check if the connector (J505) of the DC controllerPCB is mounted properly and also check if theconnector of the fixing assembly is mounted properly.- Check the wiring between the thermistor and the DCcontroller.-Check if the main thermistor is mounted properly andalso check if there is no contamination.- Replace the main thermistor.- Replace the fixing heater.- Replace the AC driver PCB.- Replace the DC controller PCB.CautionYou must clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).0010 The power has been turned off and then onwithout clearing the error.- Clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).E004 The fixing assembly is faulty.0000 The SSR used to drive the fixing heater has ashort circuit (detection by hardware circuitry).- Replace the AC driver PCB.- Replace the DC controller PCB.CautionYou will have to clear the error in service mode(COPIER>FUNCTION>CLEAR>ERR).E005 The absence of the fixing web is detected.0000 The length of the fixing web that has beentaken up is more than a specific value and thefixing web length sensor (PS7) has detectedthe absence of the web for 5 sec or more.- Check the position of the fixing web detection lever.- Replace the fixing web.- Replace the fixing web length sensor.- Replace the DC controller PCB.CautionAfter replacing the fixing web, you will have to clear thetwo web counters in service mode(COPIER>COUNTER>MISC>FIX-WEB andCOPIER>COUNTER>DRBL-1>FIX-WEB).0010 The power is turned off and then on withoutclearing the error.- Reset the counters of the two webs to zero in servicemode(COPIER>COUNTER>MISC>FIX-WEB,COPIER>COUNTER>DRBL-1>FIX-WEB)E010 The rotation of the main motor is faulty.Code Cause Remedy