2-111Cisco Catalyst Blade Switch 3130 and 3032 for Dell Command ReferenceOL-13271-03Chapter 2 Cisco Catalyst Blade Switch 3130 and 3032 for Dell Cisco IOS Commandsdiagnostic monitordiagnostic monitorUse the diagnostic monitor global configuration command to configure health-monitoring diagnostictesting. Use the no form of this command to disable testing and to return to the default settings.diagnostic monitor interval switch number test {name | test-id | test-id-range | all} hh:mm:ssmilliseconds daydiagnostic monitor switch number test {name | test-id | test-id-range | all}diagnostic monitor syslogdiagnostic monitor threshold switch number test {name | test-id | test-id-range | all} failure countcountno diagnostic monitor interval switch number test {name | test-id | test-id-range | all}no diagnostic monitor switch number test {name | test-id | test-id-range | all}no diagnostic monitor syslogno diagnostic monitor threshold switch number test {name | test-id | test-id-range | all} failurecount countSyntax Description interval Configure the interval between tests.switch number Specify the switch number, which is the stack member number. If theswitch is a standalone switch, the switch number is 1. If the switch is in astack, the range is 1 to 9, depending on the switch member numbers in thestack.This keyword is supported only on stacking-capable switches.test Specify the tests to be run.name Specify the name of the test. For more information, see the “UsageGuidelines” section.test-id Specify the ID number of the test. The range is from 1 to 7. For moreinformation, see the “Usage Guidelines” section.test-id-range Specify more than one test with the range of test ID numbers. For moreinformation, see the “Usage Guidelines” section.all Specify all of the diagnostic tests.hh:mm:ss Configure the monitoring interval in hours, minutes, and seconds. Forformatting information, see the “Usage Guidelines” section.milliseconds Configure the monitoring interval in milliseconds (ms). The range is from0 to 999 ms.day Configure the monitoring interval in the number of days. The range is from0 to 20 days. For formatting information, see the “Usage Guidelines”section.syslog Enable the generation of a syslog message when a health-monitoring testfails.