06/15 Rev. 6.00-02 USER- / SERVICE MANUAL Info-Printouts & Parameters64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)70#VW/I Interface64-xx ALX 92x DPM PEM ALX 73x (PMA)Defines the output interface belonging to the Easy-Plug command #VW/I.Easyplug (Default) Interface that is defined in INTERFACE PARA >EASYPLUGINTERPR >Interface as input interface for print data.Serial Com1 Serial interface Com 1. Only available for selection, if the interface is not occupied by anotherfunction.USB USB interface Only available for selection, if the interface is not occupied by anotherfunction.TCP/IP SOCKET Ethernet interface Only available for selection, if the interface is not occupied by anotherfunction.Serial Com3 Serial interface Com 3. Only available for selection, if the optional I/O board is installed and if theinterface is not occupied by another function.> DRIVEASSIGNMENT For detailed information read the Easy-Plug manual, topic section GeneralNotes, Definitions and Command Overview , chapter „Drive names“.Drive C64-xx ALX 92x DPM PEM ALX 73x (PMA)Assigns drive letter C: to one of the card slots.None C: is not assignedCompactFlash (Default) C: is assigned to the standard CF card slot (left slot at the 64-xx)SD card Assigns drive letter C: to the SD card slotUSB-stick C: is assigned to the USB host port.Drive E64-xx ALX 92x DPM PEM ALX 73x (PMA)Assigns drive letter E: to one of the card slots or USB ports.None E: is not assignedCompactFlash E: is assigned to the standard CF card slot (left slot at the 64-xx)SD card (Default) Assigns drive letter E: to the SD card slotUSB stick E: is assigned to the first detected USB host connector