06/15 Rev. 6.00-02 USER- / SERVICE MANUAL Info-Printouts & Parameters64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)81 The value set here remains when the factory settings are carried out.xxxx Ohm Setting range: 1000 to 1500 Ohm; Unit interval: 1 OhmSetting the print head resistance:Setting:1. From the print head, read off the resistance value to be set and make a noteof it (1000 to 1500).2. In off-line mode press the Prog. button, display: PRINT INFO.3. Press the Cut button until SYSTEM PARAMETER is displayed.4. Press the Online button, display:5. Press the Cut button until the following is displayed:6. Press the Online button, set value is displayed.7. Set the previously noted resistance value of the print head using the Feedand Cut buttons.8. Press the Online button to confirm the set value.9. Press the Prog. button to return to the display OFFLINE 0 JOBS.Temp. reduction64-xx ALX 92x DPM PEM ALX 73x (PMA)Reduction in the print head temperatureThe parameter SYSTEM PARAMETER > Temperature reduct. allows the power supplyto be reduced in the event of an increase in the print head temperature, there-by ensuring an evenly good print image.xxx% Setting range: 0 to 100%; Unit interval: 5%The following setting alternatives are available:• 0%: No temperature reduction.• xx%: Up to xx% temperature reduction with a hot print head.• Default setting: 20%. For further information refer to the user manual, topic section „AdvancedApplication“, chapter „Printing with Termperature Compensation“CAUTION!Entering a false value can damage the print head. Read off the correct value from the print head and set it accordingly.SYSTEM PARAMETERFoil end warningSYSTEM PARAMETERHead resistance