06/15 Rev. 04 USER MANUAL Advanced ApplicationsAP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x32Storing and transferring parameter settingsRecommendations• Suitable printers: All printers listed in the headline, apart from the AP 4.4 (whichhas no card slot)• Firmware:Application casesSometimes, it will be necessary to reinstall all parameter settings of a printer at a timeor to transfer the settings to another printer. In those cases, the operator can savetime, money and nerves by loading all the parameter settings completely. The follow-ing cases are possible:• After a printer is being serviced, it is supposed to get the same settings as before.• The parameter settings of one printer are supposed to be transferred to anotherprinter of the same type.• Several printers of the same type should be provided with the same settings.It is adviseable to read out and to store the parameter settings completely, to be ableto restore them later. To do so, there are two ways:Easy-Plug Reading out via the interface by means of appropriate Easy-Plug commands. This re-quires sound knowledge of the command language Easy-Plug and is not further dis-cussed here.Further information: refer to the Easy-Plug manual, topic section Description of com-mands , commands #!PG and #PC.Memory card Storing the parameter settings on a memory card in a text file („setup file“) (see de-scription below).Printer Feature Firmware version64-xx, DPM, PEM, ALX 92x Gen. 2 3.4064-xx, DPM, PEM, ALX 92x Gen. 3 5.02ALX 73x -- 6.36AP 5.4, AP 7.t -- 3.00AP 5.4 Gen II, AP 5.6 MLK 7.34[Tab. 22] Minimum firmware requirement if it is to store or transfer parameter settings.