06/15 Rev. 10 USER + SERVICE MANUAL /Status Reports64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.645 Precondition for this status message is, that parameterSYSTEM PARAMETERS > w/wo magazine is set to „with“.Measure Check, if the material in infeed 1 is loaded correctly, respectively if it´sloaded at all. Acknowledge by pressing the Online button.5057 Infeed 3 emptyStatus (TT4 only) While initializing, TT4 reports no material in infeed 1. Precondition for this status message is, that parameterSYSTEM PARAMETERS > w/wo magazine is set to „with“.Measure Check, if the material in infeed 1 is loaded correctly, respectively if it´sloaded at all. Acknowledge by pressing the Online button.5058 Infeed 4 emptyStatus (TT4 only) While initializing, TT4 reports no material in infeed 1. Precondition for this status message is, that parameterSYSTEM PARAMETERS > w/wo magazine is set to „with“.Measure Check, if the material in infeed 1 is loaded correctly, respectively if it´sloaded at all. Acknowledge by pressing the Online button.5059 Stacker fullStatus (AP 7.t only) This message can only appear if a TCS is applied asperipheral device. It indicates, that the stacker is full or the protection coveris opened.Measure Empty stacker Close cover If the message appears in spite of a closed cover and an emptied stacker,check the function of lid switch and microswitch.5060 Stacker fullStatus This message can only appear if a TCS is applied as peripheral device. Itindicates, that the stacker is full or the protection cover is opened.Measure Empty stacker Close cover If the message appears in spite of a closed cover and an emptied stacker,check the function of lid switch and microswitch.