06/15 Rev. 10 USER + SERVICE MANUAL /Status Reports64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6171115 > Limit valueStatus A sent Easy Plug command contains a value which exceeds the admissiblerange at the top limit. The faulty value is replaced automatically by a defaultvalue matching the limits.Example: #YT109/5/. The value 5 has been assigned to the parameter d.Admissible for d are the values 0, 1, 2, 3. Therefore, 5 exceeds the valuerange at the top limit.Measure Check the Easy Plug command on admissible values and correct them ifnecessary. Please read the notes in section Easy-Plug errors .1120 Incorr. logo no.Status Logo no. is invalid because it is outside of the address field. (self-acknowledging)Measure Check whether the logo no. has been given as being smaller than 0 (zero)or larger than 255.1121 Logo existsStatus Logo already exists.Measure Change the designation of the logo; repeat saving.1122 Creating logoStatus General software errorMeasure Please read the notes in section General software errors .1123 Rename logoStatus General software errorMeasure Please read the notes in section General software errors .1124 Logo fileStatus General software errorMeasure Please read the notes in section General software errors .1125 Delete errorStatus General software errorMeasure Switch printer off and then back on again after thirty seconds. Please read the notes in section General software errors .