06/15 Rev. 10 USER + SERVICE MANUAL /Status Reports64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6281504 Param > MaxError level 1Status Parameter exceeds the maximum value definedMeasure Shorten the parameter.1505 Param < MinError level 1Status Parameter is shorter than the admissible minimum value allowed.Measure Modify the parameter.1506 No PreviousError level 1Status Graphics command is to set current row data to previous row data, butprevious row data doesn't exist.Measure 1507 Not enough dataError level 1Status Data for graphics command is not enough.Measure Check and modify graphics data.1508 String Too LongError level 1Status String characters exceeds the maximum number of characters which theparticular string parameter can take.Measure Check and modify the command.1509 Wrong Byte CntsError level 1Status The row size or total size parameters is not valid (equals 0). Occurs whendownload graphic or download font commands in process.Measure Check and modify the command.1510 Wrong ParamError level 1Status Control characters are not allowed for discrete parameter (single letterparameter).Measure Check and modify the command.1511 Bar Parm ErrorError level 1