06/15 Rev. 10 USER + SERVICE MANUAL /Status Reports64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6342500 Multiple textsStatus This status number may be combined with variety of texts, which all aregenerated by the Basic interpreter. The Basic interpreter is a function whichis not realeased nor supported.Measure Switch off the Basic interpreter (SYSTEM PARAMETERS > Print Interpret.).3000/3003/3006/3012/3015 Com x OverrunStatus Receive error at the RS232 interface COMx (x = [1…5]).Measure Acknowledge by pressing the Online button.3001/3004/3007/3013/3016 Com x ParityStatus Receive error at the RS232 interface COMx (x = [1…5]).Measure Acknowledge by pressing the Online button. Check parameter setting at printer (INTERF. PARAM. > COM1 PORT > Parity) andPC. Notes about setting the printer parameters are given in the chapter "InfoPrint-outs and Parameters" in the User Manual.3002/3005/3008/3015/3017 Com x FrameStatus Receive error at the RS232 interface COMx (x = [1…5]).Measure Acknowledge by pressing the Online button. Check parameter setting at printer (INTERF. PARAM. > COM1 PORT > Baud rateand INTERF. PARAM. > COM1 PORT > stop bits) and PC. Notes about setting the printer parameters are given in the chapter "InfoPrint-outs and Parameters" in the User Manual.3010 Spooler OverflowStatus Fault which is caused by a faulty handshake at an interface. Theconsequence is an overflowing data buffer at the printer, because the hostdoesn´t stop to send data to the printer.Measure Acknowledge by pressing the Online button. Check the connections of the data line, especially the signal wiresbelonging to the handshake. Check the interface settings, especially the handshake settings.3011 Send buffer fullStatus The send buffer is full. This error may happen, if the printer status wasrequested several times (#!Xn), but the status reply was not read out.Measure Make sure that the status reply is read out.