06/15 Rev. 6.00-02 USER- / SERVICE MANUAL Info-Printouts & Parameters64-xx – DPM – PEM – ALX 92x – ALX 73x (PMA)110• It is not recommended to use the setting „Fast legacy“ as a standard, assome unexpected behavior, depending on the label format, may occur.Each label format has to be tested explicitly.fast Standard verification mode.slow Each print job is proceeded as if it contained counting fields. Additionally,each labels is moved forward underneath the laser beam and backwardsagain. This procedure slows down the label throughput, but on the other handit ensures that the correct counting field content is printed after an error oc-cured.Ref Decode64-xx ALX 92x DPM PEM Only if OLV PARAMETER > Cancel. printing = „On“.No Test The bar code doesn´t have to be decodable.Pass The bar code must be decodable.Decodability64-xx ALX 92x DPM PEM Only if OLV PARAMETER > Cancel. printing = „On“. Condition: Value >= Limit.xxx Setting range: -1 to 100; Unit interval: 1; -1 = No checking.Modulation64-xx ALX 92x DPM PEM Only if OLV PARAMETER > Cancel. printing = „On“. Condition: Value >= Limit.xxx Setting range: -1 to 100; Unit interval: 1; -1 = No checking.Defects64-xx ALX 92x DPM PEM Only if OLV PARAMETER > Cancel. printing = „On“. Condition: Value <= Limit.xxx Setting range: -1 to 100; Unit interval: 1; -1 = No checking.Edge contrast64-xx ALX 92x DPM PEM Only if OLV PARAMETER > Cancel. printing = „On“. Condition: Value >= Limit.xxx Setting range: -1 to 100; Unit interval: 1; -1 = No checking.