06/15 Rev. 10 USER + SERVICE MANUAL /Status Reports64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6595550 Wrong tag typeStatus A transponder type was detected, which is not known by the reader – itcannot be used.Measure Use another transponder type, which is known to the reader.5551 Max Tags failedStatus The maximum permissible number of invalid labels was reached. Thisvalue is to be set via parameter RFID PARAMETERS > Max Tags To Stop. Invalid labels are being printed on with diagonal stripes.Measure Find out, why the labels are invalid; put things right. Increase the maximum value.5560 TCS full / coverStatus This message can only appear, if a TCS is applied as peripheral device.The message shows up, if:• the stacker is full• the stacker cover is openMeasure Empty the stacker, or close the cover5590 Odd hex stringStatus A character string was sent to the transponder (Easy Plug command #RFS)and was ought to be interpreted hexadecimal (use #RFS with parameter"B"). For this, the character string must consist of an equal number ofcharacters. This was not the case, what triggered this error message.Measure Send an equal number of characters.5600 Job without #QStatus The print job misses the declaration of the print amount (Easy-Plugcommand #Q).Measure Insert a #Q command with the print amount.5601 Job memory fullStatus The job memory for Easy-Plug printjobs is full.Measure Reduce the reserved memory for one or more of the following memoryareas:• Free store size (SYSTEM PARAMETER > Free store size)• RAM disk size (SYSTEM PARAMETER > Ram disk size)• Font download size (SYSTEM PARAMETER > Font downl. area) If there are already some printjobs in the printer queue: wait until those areprocessed.6000 Param. incorrectStatus Novram check sum error.