06/15 Rev. 10 USER + SERVICE MANUAL /Status Reports64-xx – DPM – PEM – ALX 73x (PMA) – LPA 81x (Printer) – ALX 92x – AP 5.4 – AP 5.6708801 Maxicode Sys noStatus Maxicode: incorrect system no.Measure Correct system no.8802 Maxicode ZipcodeStatus Maxicode: incorrect zipcode.Measure Correct zipcode.8803 Maxicode ClassStatus Maxicode: faulty class code.Measure Correct class code.8804 Maxi. Sec. mess.Status Maxicode: secondary message has an illegal length.Measure Correct length of secondary message.8805 Maxicode CountryStatus Maxicode: faulty country code.Measure Correct country code.8830 Cod49 DatalengthStatus The user data string is too long. Not all characters can be coded in the barcode. The bar code is not printed.Measure Shorten the data string.8031 Cod49 wrong dataStatus The data string contains wrong characters. The bar code is not printed.Measure Correct the content of the data string.8850 Unknown filetypeGraphic files with the extention declared in the Easy Plug command #YGare not supported.Measure Transform the graphics file into another file format or use another graphic ina supported format. Check, if the spelling of the file extention is correct.8851 Graphic openStatus The graphics file declared in the Easy Plug #YG command cannot be foundon the compactflash card. Possible reasons are:• Path and/or designation of the graphics file stored on the compactflash carddoesn´t match the path and/or designation declared by the #YG command.• The file is not available on the compactflash card.